MT-OPTICS OEM MULTI-ORDER WAVEPLATES SOLUTION
Nov 12, 2026
Wave retarders are used widely in applications like rotating polarization, transforming between linear and circular polarization. MT-OPTICS offers quarter- and half-wave plates in a variaty of options.
Introduction:
Wave retarders are used widely in applications like rotating polarization, transforming between linear and circular polarization. MT-OPTICS offers quarter- and half-wave plates in a variaty of options including Multiple Order Waveplates, Cemented Zero-Order Waveplates, Airspaced Zero-Order Waveplates, True Zero-Order Waveplates, Dual Wavelength waveplates. MT-OPTICS’s waveplates feature high precision, high damage threshold level and more importantly, we have the capacity to design and customize specific ideal waveplates to fit your exact application.
Features:
· Material: Crystal Quartz, MgF2
· Custom dimension and shapes
· Diameter from 5 to 100 mm
· Standard and custom coating options available
· High laser damage threshold
· Mounted and unmounted waveplates are available
Specifications:
Material
Crystal Quartz
Diameter Tolerance
+0/-0.25mm
Clear Aperture
≥ central 90% of diameter
Retardance Accuracy
<λ/300
Surface Quality
20/10
Wavefront Distortion
λ/10 @632.8nm over the clear aperture
Parallelism
≤3″
Coating
R<0.25%
Damage Threshold
2MW/cm2,2J/cm2,10ns
• Wide Temperature Bandwidth
• MT-OPTICS’s standard coatings are available
• Custom designs for other sizes and coatings are also vailable upon request.
Single Wavelength Waveplates
Standard Wavelength (λ):
Wavelength
248nm
413nm
514.5nm
632.8nm
800nm
1064nm
266nm
441.6nm
532nm
647.1nm
830nm
1300nm
308nm
457.9nm
543.5nm
676.4nm
850nm
1315nm
351nm
488nm
594nm
694.3nm
905nm
1320nm
354.7nm
510.5nm
611.9nm
780nm
1050nm
1550nm
Dual Wavelength Waveplates
Dual wavelength waveplate is widely used on Third Harmonic Generation (THG) system. When you need a NLO crystal for type II SHG (o+e→e), and a NLO crystal for type II THG (o+e→e), the out put polarization from SHG can not be used for THG. So you must turn the polarization to get two perpendicular polarization for type II THG. Dual wavelength waveplate works like a polarizing rotator, it can rotate the polarization of one beam and remain another beam's polarization. Also the dual wavelength waveplate can be applied to following systems:
• Type II SHG + Type II THG
• Type II SHG + Type I THG
• Type I SHG + Type I THG
For example: we use KTP as SHG type II and LBO as THG type II, but the polarization of output beam from KTP is not optimized for THG type II. When we use a dual wavelength waveplate as drawing, it can change the 532nm beam to a special angle polarization but not change 1064nm beam at all.
Specifications:
Material
Crystal Quartz
Diameter Tolerance
+0/-0.25mm
Clear Aperture
≥ central 90% of diameter
Retardance Accuracy
<λ/100
Surface Quality
20/10
Wavefront Distortion
λ/10 @ 632.8nm over the clear aperture
Parallelism
≤3″
Coating
Laser Line V AR Coating R<0.25%< span="">
Damage Threshold
2MW/cm2,2J/cm2,10ns
Standard Retardation:
Wavelength 1-Wavelength2
W1064-W532(nm)
W1064-W532(nm)
W532-W266(nm)
W532-W355(nm)
Retardation 1-Retardation2
λ-λ/2
λ/2-λ
λ/4-λ/2
λ/2-λ/4
Note:
• Custom designs for other sizes ,coatings and holders are also available upon request.
• MT-OPTICS's standard coatings are available upon request.
Category:Polarization Optics/ Waveplates